ACCURATE
   TEMPERATURE
      CONTROL
         CORPORATION

PLASTICS INDUSTRY THERMOCOUPLES
FIVE TERMINAL JACK PANELS
(FOR USE TO 900o F)
Bayonet

Compression Fitting

Five Terminal Jack Panels

Nozzle

Adjustable

MgO

Miniature and MgO Insulation

Accessories

Base Metal

Wire
The inserts are used in groups of five. These are the same inserts as used in the jacks. Six standard thermocouple alloy types are available. Panels are supplied with all five positions for the same type of thermocouple. The body is made of phenolic and drilled for flush mounting. It may be mounted on a control panel or to a conduit box.
Each conneciton is identified as to thermocouple type by etched aluminum discs on panel face.

Connections are made to large terminal screws on the rear of the panel. For more than five connections comvine with other jack panels for each multiple of five.
CATALOG
NUMBER
CALIBRATION
3520 (J) Iron/
Constantan
3522 (K) Chromel/
Alumel
3524 (R) or (S)
Plat./Plat.
& Rhodium
3526 (T) Copper/
Constantan
  ADJUSTABLE THERMOCOUPLES
RIGID MODEL:
Plain end 1/8" O.D. Thermocouples for Adjustable Bayonet Fitting.
BEND CATALOG
NUMBER
STRAIGHT 1504
450 1506
900 1508

Adjustable bayonet No. 1501 converts the plain 1/8" O.D. thermocouple to rigid adjustable bayonet thermocouple. Permits stocking one "A" dimension to suit several hole depths. Order plain 1/8" O.D. thermocouple and No. 1501 fitting separately. Specify "A" and "B" dimension for thermocouple
MELT THERMOCOUPLES

Used to seal hole if thermocouple is removed from extruder.
RIGID BODY 4" FLEXIBLE ARMOR BLANK
BOLT
CONSTRUCTION
Flush 1/4" 1/2" 3/4" Flush 1/4" 1/2" 3/4" IMMERSION LENGTH "A"
1431 1433 1434 1435 1436 1437 1438 1439 BODY LENGTH 3"      "L"
1461 1462 1463 1464 1465 1466 1467 1468 1469 BODY LENGTH 6"      "L"
RECOMMENDED DRILLING DIMENSIONS FOR PROPER MOUNTING IN EXTRUDER
NOTE: Melt Thermocouple uses 24 ga. thermocouple element and threads are 1/2-20 NF calibration is ISA standard grade Iron/Constantan, others available on request.